IMAGE: Scottish Fire and Rescue Service crest showing a red shield with a white cross, topped by a crown.
FIRE SAFETY CHECKLIST TEMPORARY STRUCTURES
See https://firescotland.gov.uk/ for details of fire laws
1. DETAILS OF APPLICANT
| NAME | ||
| ADDRESS | ||
| TELEPHONE NO. | MOBILE NO. |
2. DATE OF EVENT
| DATE | |
| DURING THE HOURS OF |
3. ADDRESS AND LOCATION OF STRUCTURE (TO INCLUDE MAP REFERENCES)
| ADDRESS AND LOCATION | |
| MAP REFERENCES |
4. THE PURPOSE FOR WHICH THE STRUCTURE IS TO BE USED
| PURPOSE |
5. MAXIMUM NUMBER OF PERSONS ALLOWED TO BE IN THE STRUCTURE (AT ANY ONE TIME)
6. IS SEATING PROVIDED? YES or NO
| TYPE OF SEATING (FIXED/MOVEABLE/TABLES AND CHAIRS) | |
| NUMBER OF CHairs TO BE PROVIDED | |
| NUMBER OF TABLES TO BE PROVIDED | |
| SIZE OF TABLES TO BE PROVIDED |
7. DETAILS OF THE STRUCTURE, FABRIC AND LININGS
(a) Tented Structures (see Guidance Note 7 Requirements Under British Standard 7837:1996)
| DOES THE FABRIC MEET THE APPROPRIATE LEVEL OF PERFORMANCE IN ITS BEHAVIOUR IN FIRE? YES or NO | |
| DOES THE FABRIC HAVE A VALID TEST CERTIFICATE? YES or NO | |
| TO WHAT STANDARD IS THE FABRIC TESTED? |
(b) Buildings
| DETAILS OF CONSTRUCTION AND COMPOSITION OF STRUCTURAL ELEMENTS |
8. EMERGENCY EXITS (see Guidance Note 8 Emergency Exits)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO. 8 BEING COMPLIED WITH? YES or NO
(a) Tented Structure
| TYPE OF EXIT PROVIDED i.e. fixed frame door velcro break out panel | |
| SIZE OF EXITS (clear unobstructed widths) |
(b) Buildings
| DIRECTION OF DOOR OPENINGS | |
| TYPE OF SECURING DEVICE FOR DOOR/DOORS | |
| SIZE OF EXITS (clear unobstructed width) |
9. MEANS OF FIREFIGHTING (see Guidance Note 9 Means for Firefighting)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO. 9 BEING COMPLIED WITH? YES or NO
DETAILS OF FIREFIGHTING EQUIPMENT AVAILABLE FOR USE IN AND AROUND THE STRUCTURE
| TYPE OF EQUIPMENT | NUMBER/SIZE | LOCATION | IS EQUIPMENT REGULARLY MAINTAINED |
|---|---|---|---|
10. NATURE AND QUANTITY OF ANY EXPLOSIVE OR HIGHLY FLAMMABLE MATERIALS STORED OR USED IN OR AROUND THE STRUCTURE, e.g. FUELS FOR HEATING, LIGHTING AND COOKING, FIREWORKS OR PYROTECHNICS
| MATERIAL | QUANTITY | LOCATION AND USE | METHOD OF STORAGE |
|---|---|---|---|
11. MEANS FOR GIVING WARNING (see Guidance Note 11 Means for Giving Warning)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO. 11 BEING COMPLIED WITH? YES or NO
WHAT PROVISION IS MADE FOR GIVING WARNING IN CASE OF FIRE?
12. LIGHTING (see Guidance Note 12 Lighting)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO. 12 BEING COMPLIED WITH? YES or NO
WHAT PROVISION IS MADE FOR EMERGENCY LIGHTING?
13. SITE MANAGEMENT (see Guidance Note 13 Site Management)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO.13 BEING COMPLIED WITH? YES or NO
WHAT PROVISION IS MADE FOR CALLING THE FIRE SERVICE?
14. STEWARDS (See Guidance Note 14 Stewards)
ARE ALL THE APPLICABLE REQUIREMENTS IMPOSED BY GUIDANCE NOTE NO. 14 BEING COMPLIED WITH? YES or NO
NUMBER OF STEWARDS PROVIDED
| STEWARDS NAMES | ADDRESS |
|---|---|
15. PROVIDE A SKETCH PLAN OF THE STRUCTURE AND SITE LAYOUT.
THE FOLLOWING ITEMS MUST BE CLEARLY ILLUSTRATED.
- (a) Floor Size
- (b) Seating Plan (if appropriate)
- (c) Emergency Exits – Position, Size and type (see Guidance Note 8)
- (d) Position of Fire Points, Hydrants or Other Water Supplies
- (e) Emergency Access Roads Around the Structure for Fire Appliances
| Please tick (✓) as appropriate | Yes | No | N/A |
|---|---|---|---|
| Have you carried out a Fire Safety Risk Assessment for the premises? (See guidance notes including reference to sector specific guide which should be kept on the premises) |
IF YOU HAVE ANSWERED NO TO ANY QUESTION YOUR FIRE SAFETY PROVISIONS ARE INADEQUATE AND REQUIRE IMMEDIATE ATTENTION
I agree to the information provided in this form being shared with the Fire Authority.
DECLARATION: I declare that the above Fire Safety Checklist has been completed accurately and that all inadequate provisions have been rectified.
Signed (Applicant) ............................................................................
Date ............................................................
Print name ............................................................................
You are requested to complete this Fire Safety Checklist and send it to your local Fire and Rescue Service Office at: Scottish Fire and Rescue Service, 16 Harbour Road, Inverness IV1 1TB
Failure to do this may result in delay in the processing of your application and/or an objection by the local Fire and Rescue Service.
GUIDANCE NOTES
For
FIRE SAFETY CHECKLIST
For compliance with
The Fire (Scotland) Act 2005 Part 3
The Fire Safety (Scotland) Regulations 2006
To the Applicant: You have received a Fire Safety Checklist form as part of the application pack for your registration/variation. Please complete the form and sign the declaration at the end. By doing so you will declare that your premises are safe for your customers and staff, and you have complied with the fire safety regulations above. Please note:
- The Fire and Rescue Service may inspect your premises to confirm your compliance, or to enforce the regulations if necessary
- Processing of your application may be delayed if you do not provide a completed Fire Safety Checklist and/or may attract an objection from the local Fire and Rescue Service.
These guidance notes are intended as basic guide to help you complete the Fire Safety Checklist. The notes contain basic guidance only. For guidance that is more detailed you should read the sector specific guidance within the information on https://firescotland.gov.uk/ or ask your local Fire Safety Enforcement Officer for advice.
Who should complete the Fire Safety Checklist?
You, the applicant, should complete the form. Within the regulations above you are considered the Responsible Person, as you will have responsibility for the management, including fire safety management, of the premises. You should also be the person most able to complete the Fire Safety Checklist (Appendix 1 or 1(a)) due to your knowledge of your premises, and to rectify any deficiencies before submitting your application. If you choose to nominate someone else to carry out the Checklist, you must still sign the declaration and take responsibility for any deficiencies.
How should the Fire Safety Checklist be completed?
The Fire Safety Checklist is a basic survey of the fire safety measures in your premises. It asks the same questions that you should ask when carrying out a full risk assessment. Answers are limited to Yes, No or Not Applicable (N/A) and you simply tick the relevant box. To help you, some boxes are blanked out, as these answers would be incorrect.
Take time to read these guidance notes and the form and then inspect/review the Fire Safety provision within the premises. Review your fire safety risk assessment (you could review it at the same time), log book and other relevant records. If you do not personally carry out any tests or training, speak to the person who does. These simple steps should give you all the information you need.
How do I know what is inadequate?
Most fire safety precautions are based upon common sense. For example, if a self-closing fire door is wedged open it is inadequate, but can be fixed by removing the wedge and instructing staff. Competent persons should maintain more complex precautions, such as fire alarm systems, and you should have records of this in your logbook. If in doubt, you could test a system to make sure it works.
If any fire safety precaution is inadequate, or you are not sure, answer NO. After the survey, you should plan how you will rectify the inadequacies.
Completing the Fire Safety Checklist Form
Applicant Information
Please ensure that your name and address are clearly legible.
Fire Risk Assessment
The Fire Safety Regulations above require a Responsible Person to carry out a fire risk assessment in the workplace. This is usually the person responsible for management in the workplace. The Risk Assessment should:
- assess the risk of fire in the premises, and any control measures that can reduce risk,
- check that fire can be detected in a reasonable time and people can be warned of fire,
- check that all people in the premises can evacuate safely,
- provide suitable fire fighting equipment,
- ensure that those in the premises know what to do in the event of fire, and
- Ensure testing and maintenance of fire safety equipment and systems takes place.
As you are applying for a licence under the Licensing (Scotland) Acts there must be a written record of the significant findings of the assessment. Any action plan resulting from the assessment should also be recorded. The fire risk assessment should be reviewed at least once a year, or when there are significant changes in staff, layout process or fire loading in the premises. Note the checklist does not constitute the full Fire Risk Assessment required by the 2005 Act.
Escape Routes and Doors
All escape routes must be kept clear and available for use at all times that the premises are occupied. You should not store anything that would obstruct or any flammable on an escape route, even temporarily. For guidance, an escape route should not be narrower than any doorway on the route. Fire exit signs and notices are used to direct people to the escape route and as such must be visible and legible. If in doubt, try following the escape route yourself.
For security reasons an emergency exit door can be secured with a push bar/pad or similar device. These must work easily, without undue pressure them. Emergency exits must not be locked when the building is occupied.
Some doors are fire resisting and self-closing. These are designed to stop fire spread, giving more time for escape and reducing damage. They are only effective if they are a good fit in the frame, close fully from any angle and are not wedged or held open.
Fire Fighting Equipment
The number, type and location of fire extinguishers should be determined by the fire risk assessment. Usually you will need to provide fire extinguishers for general firefighting and to cover special risks. If you have a kitchen, you will also need a fire blanket for the hazards associated with cooking.
General
the most common general fire extinguisher is the water type. As a rule of thumb, you should provide one 9-litre water extinguisher per 200 square metres of floor area, with at least two extinguishers per floor (or one per floor if the floor area is less than 100 square metres). Other types that can be used are foam, AFFF (sometimes-called light water or spray foam), dry powder or carbon dioxide, but the size needed varies according to the type and size of risk. Fire extinguishers for general firefighting should be sited on escape routes, at or near the final exit.
Special Risk
risks such as computer rooms, electrical equipment, large fridges etc. will need fire extinguishers that are appropriate to the risk, do not cause injury to the user, or cause undue to the equipment. You should seek specialist advice about fire extinguishers for special risks.
Fire Warning Systems and Automatic Fire Detection
All registered premises should have a means of warning staff and customers that there is a fire, so that they can make their escape. The type of system is determined by the fire risk assessment and must take into account the layout, background noise, staff locations etc. and whether any person (staff or customers) can use the system without putting themselves in further danger.
The type of system can range from simple break glass call-points, with a bell or siren, to complex systems with automatic smoke or heat detectors, a control